Perkins is one of the world’s leading diesel engine manufacturers since 1932, nearly 400,000 units for one year, quickly occupied the world market for the full specification, good structure, reliable performance, easy maintenance, low exhaust, long period maintenance. In the auto car, construction, agricultural, industrial and marine markets, major original equipment manufacture choose Perkins Engines because of its fuel, nature gas elding for reliable and durable use.
Technical Parameter of Gensets Powered by Perkins :
"MP" SERIES - 50Hz
| Genset Model |
Genset Prime Power |
Genset Standby Power |
brand new UK Original Perkins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
Tech Data |
| kVA |
kVA |
Model |
kW |
Model |
kVA |
Click for detail data |
| MPS9-1 |
9 |
10 |
403D-11G |
9.3 |
BCI 164B |
11 |
 |
| MPS13-1 |
13 |
14.5 |
403D-15G |
13.3 |
BCI 164C |
13.5 |
 |
| MPS20-1 |
20 |
22 |
404D-22G |
20.3 |
BCI 184E |
22.5 |
 |
| MPS27-1 |
27 |
30 |
404D-22TG |
27 |
BCI 184F |
27.5 |
 |
| MPS30-1 |
30 |
33 |
1103A-33G |
30.4 |
BCI 184G |
31.3 |
 |
| MPS45-1 |
45 |
50 |
1103A-33TG1 |
45.6 |
UCI 224D |
50 |
 |
| MPS60-1 |
60 |
66 |
1103A-33TG2 |
59.3 |
UCI 224E |
60 |
 |
| MPS65-1 |
65 |
72 |
1104A-44TG1 |
64.3 |
UCI 224F |
72.5 |
 |
| MPS80-1 |
80 |
88 |
1104A-44TG2 |
79.1 |
UCI 224G |
85 |
 |
| MPS100-1 |
100 |
110 |
1104C-44TAG2 |
99.5 |
UCI 274C |
100 |
 |
| MPS136-1 |
136 |
150 |
1006TAG |
133.5 |
UCI 274E |
140 |
 |
| MPS150-1 |
150 |
165 |
1006TAG2 |
143 |
UCI 274F |
160 |
 |
| MPS185-1 |
185 |
205 |
1106C-E66TAG4 |
175.5 |
UCI 274G |
182 |
 |
| MPS200-1 |
200 |
225 |
1306C-E87TAG3 |
199 |
UCI 274H |
200 |
 |
| MPS230-1 |
230 |
253 |
1306C-E87TAG4 |
217 |
UCI 274J |
230 |
 |
| MPS250-1 |
250 |
275 |
1306C-E87TAG6 |
239 |
UCI 274K |
250 |
 |
| MPS350-1 |
350 |
400 |
2206A-E13TAG2 |
349 |
HCI 444E |
350 |
 |
| MPS400-1 |
400 |
450 |
2206A-E13TAG3 |
392 |
HCI 444F |
400 |
 |
| MPS450-1 |
450 |
500 |
2506C-E15TAG1 |
435 |
HCI 544C |
500 |
 |
| MPS500-1 |
500 |
550 |
2506C-E15TAG2 |
478 |
HCI 544D |
550 |
 |
| MPS600-1 |
600 |
660 |
2806A-E18TAG1A |
574 |
HCI 544E |
610 |
 |
| MPS650-1 |
650 |
700 |
2806C-E18TAG2 |
609 |
HCI 544F |
670 |
 |
| MPS730-1 |
730 |
800 |
4006-23TAG2A |
685 |
LVI 634B |
750 |
 |
| MPS800-1 |
800 |
900 |
4006-23TAG3A |
760 |
LVI 634C |
800 |
 |
| MPS850-1 |
850 |
935 |
4008TAG |
787 |
LVI 634D |
910 |
 |
| MPS905-1 |
905 |
996 |
4008TAG1A |
839 |
LVI 634D |
910 |
 |
| MPS1022-1 |
1022 |
1125 |
4008TAG2A |
947 |
HCI 634J |
1030 |
 |
| MPS1253-1 |
1253 |
1385 |
4012-46TWG2A |
1166 |
PI 734A |
1260 |
 |
| MPS1364-1 |
1364 |
1500 |
4012-46TWG3A |
1263 |
PI 734B |
1400 |
 |
| MPS1505-1 |
1505 |
1656 |
4012-46TAG2A |
1395 |
PI 734C |
1550 |
 |
| MPS1705-1 |
1705 |
1875 |
4012-46TAG3A |
1579 |
PI 734E |
1900 |
 |
| MPS1752-1 |
1752 |
1928 |
4016TAG |
1607 |
PI 734E |
1900 |
 |
| MPS1844-1 |
1844 |
2028 |
4016TAG1A |
1690 |
PI 734E |
1900 |
 |
| MPS2058-1 |
2058 |
2263 |
4016TAG2A |
1886 |
PI 734F |
2080 |
 |
"MP" SERIES - 60Hz
| Genset Model |
Genset Standby Power |
Genset Prime Power |
brand new UK Original Perkins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
Tech Data |
| kW |
kW |
Model |
kW |
Model |
kW |
Click for detail data |
| MPS10-2 |
10 |
9 |
403D-11G |
11.4 |
BCI 164B |
11 |
 |
| MPS14-2 |
14 |
13 |
403D-15G |
15.9 |
BCI 164C |
13.5 |
 |
| MPS20-2 |
20 |
18 |
404D-22G |
23.9 |
BCI 184E |
24 |
 |
| MPS28-2 |
28 |
25 |
404D-22TG |
32.6 |
BCI 184F |
28 |
 |
| MPS30-2 |
30 |
28 |
1103A-33G |
35.4 |
BCI 184F |
28 |
 |
| MPS50-2 |
50 |
45 |
1103A-33TG1 |
53.9 |
UCI 224C |
44 |
 |
| MPS60-2 |
60 |
55 |
1103A-33TG2 |
67.5 |
UCI 224E |
60 |
 |
| MPS65-2 |
65 |
60 |
1104A-44TG1 |
75.5 |
UCI 224E |
60 |
 |
| MPS80-2 |
80 |
73 |
1104A-44TG2 |
90.2 |
UCI 224F |
75 |
 |
| MPS100-2 |
100 |
90 |
1104D-E44TAG2 |
111 |
UCI 274C |
100 |
 |
| MPS135-2 |
135 |
123 |
1006TAG |
147 |
UCI 274E |
143 |
 |
| MPS140-2 |
140 |
127 |
1106C-E66TAG2 |
155.3 |
UCI 274E |
143 |
 |
| MPS150-2 |
150 |
136 |
1106C-E66TAG3 |
163.4 |
UCI 274E |
143 |
 |
| MPS180-2 |
180 |
164 |
1106C-E66TAG4 |
196.3 |
UCI 274F |
165 |
 |
| MPS200-2 |
200 |
182 |
1306C-E87TAG3 |
220 |
UCI 274G |
185 |
 |
| MPS215-2 |
215 |
195 |
1306C-E87TAG4 |
235 |
UCI 274H |
204 |
 |
| MPS350-2 |
350 |
320 |
2206A-E13TAG5 |
381 |
HCI 444ES |
335.2 |
 |
MP EU SERIES - 50Hz
| Genset Model |
Genset Prime Power |
Genset Standby Power |
brand new UK Original Perkins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
Tech Data |
| kVA |
kVA |
Model |
kW |
Model |
kVA |
Click for detail data |
| MPS20-1E |
20 |
22 |
404D-22G |
20.3 |
BCI 184E |
22.5 |
 |
| MPS27-1E |
27 |
30 |
404D-22TG |
27 |
BCI 184F |
27.5 |
 |
| MPS30-1E |
30 |
33 |
1103C-33G3 |
30.4 |
BCI 184G |
31.3 |
 |
| MPS45-1E |
45 |
50 |
1103C-33TG3 |
45.6 |
UCI 224D |
50 |
 |
| MPS60-1E |
60 |
66 |
1104C-44TG3 |
59.3 |
UCI 224E |
60 |
 |
| MPS80-1E |
80 |
90 |
1104C-44TAG1 |
79 |
UCI 224G |
85 |
 |
| MPS100-1E |
100 |
110 |
1104C-44TAG2 |
99.5 |
UCI 274C |
100 |
 |
| MPS135-1E |
135 |
150 |
1106C-E66TAG2 |
133 |
UCI 274E |
140 |
 |
| MPS150-1E |
150 |
165 |
1106C-E66TAG3 |
143.5 |
UCI 274F |
160 |
 |
| MPS180-1E |
180 |
200 |
1106C-E66TAG4 |
175.5 |
UCI 274G |
182 |
 |
| MPS200-1E |
200 |
225 |
1306C-E87TAG3 |
199 |
UCI 274H |
200 |
 |
| MPS230-1E |
230 |
253 |
1306C-E87TAG4 |
217 |
UCI 274J |
230 |
 |
| MPS250-1E |
250 |
275 |
1306C-E87TAG6 |
239 |
UCI 274K |
250 |
 |
| MPS350-1E |
350 |
400 |
2206C-E13TAG2 |
349 |
HCI 444E |
350 |
 |
| MPS400-1E |
400 |
450 |
2206C-E13TAG3 |
392 |
HCI 444F |
400 |
 |
| MPS450-1E |
450 |
500 |
2506C-E15TAG1 |
435 |
HCI 544C |
500 |
 |
| MPS500-1E |
500 |
550 |
2506C-E15TAG2 |
478 |
HCI 544D |
550 |
 |
| MPS600-1E |
600 |
660 |
2806C-E18TAG1A |
565 |
HCI 544E |
610 |
 |
MP EPA SERIES - 60Hz
| Genset Model |
Genset Standby Power |
Genset Prime Power |
brand new UK Original Perkins Engine |
Engine Max. Power |
brand new Stamford Alternator |
Alternator Prime Power |
Tech Data |
| kW |
kW |
Model |
kW |
Model |
kW |
Click for detail data |
| MPS10-2E |
10 |
9 |
403D-11G |
11.4 |
BCI 164B |
11 |
 |
| MPS14-2E |
14 |
13 |
403D-15G |
15.9 |
BCI 164C |
13.5 |
 |
| MPS20-2E |
20 |
18 |
404D-22G |
23.9 |
BCI 184E |
24 |
 |
| MPS28-2E |
28 |
25 |
404D-22TG |
32.6 |
BCI 184F |
28 |
 |
| MPS30-2E |
30 |
28 |
404D-22TAG |
35.7 |
BCI 184F |
28 |
 |
| MPS55-2E |
55 |
50 |
1104D-44TG1 |
63 |
UCI 224D |
52 |
 |
| MPS65-2E |
65 |
59 |
1104D-E44TG1 |
71.8 |
UCI 224E |
60 |
 |
| MPS80-2E |
80 |
73 |
1104D-E44TAG1 |
90.8 |
UCI 224F |
75 |
 |
| MPS100-2E |
100 |
90 |
1104D-E44TAG2 |
111 |
UCI 274C |
100 |
 |
| MPS140-2E |
140 |
125 |
1106D-E66TAG2 |
153.6 |
UCI 274E |
243 |
 |
| MPS150-2E |
150 |
135 |
1106D-E66TAG3 |
159.4 |
UCI 274E |
165 |
 |
| MPS175-2E |
175 |
156 |
1106D-E66TAG4 |
192.3 |
UCI 274F |
165 |
 |
| MPS350-2E |
350 |
320 |
2206D-E13TAG2 |
381 |
HCI 444ES |
335.2 |
 |
| MPS400-2E |
400 |
350 |
2206D-E13TAG3 |
435 |
HCI 444E |
352 |
 |
| MPS450-2E |
450 |
400 |
2506D-E15TAG1 |
490 |
HCI 444F |
400 |
 |
| MPS500-2E |
500 |
455 |
2506C-E15TAG3 |
543 |
HCI 544C |
475 |
 |
| MPS600-2E |
600 |
545 |
2806C-E18TAG3 |
652 |
HCI 544E |
600 |
 |